ChecklistGuro logo ChecklistGuro Solutions Secteurs d'activité Ressources Tarifs

Roof Drainage System Inspection Checklist

Ensure your construction projects stay dry! Download our free Roof Drainage System Inspection Checklist - a vital tool for preventing costly water damage. Protect your building with this comprehensive guide for contractors and inspectors.

Ce modèle a été installé 1 fois.

Style d'affichage

General Information

1 of 10

Details about the project and inspector.

Project Name

Project Address

Inspection Date

Inspection Time

0:00
0:15
0:30
0:45
1:00
1:15
1:30
1:45
2:00
2:15
2:30
2:45
3:00
3:15
3:30
3:45
4:00
4:15
4:30
4:45
5:00
5:15
5:30
5:45
6:00
6:15
6:30
6:45
7:00
7:15
7:30
7:45
8:00
8:15
8:30
8:45
9:00
9:15
9:30
9:45
10:00
10:15
10:30
10:45
11:00
11:15
11:30
11:45
12:00
12:15
12:30
12:45
13:00
13:15
13:30
13:45
14:00
14:15
14:30
14:45
15:00
15:15
15:30
15:45
16:00
16:15
16:30
16:45
17:00
17:15
17:30
17:45
18:00
18:15
18:30
18:45
19:00
19:15
19:30
19:45
20:00
20:15
20:30
20:45
21:00
21:15
21:30
21:45
22:00
22:15
22:30
22:45
23:00
23:15
23:30
23:45

Inspector Name

Inspector Company

Project Phase (e.g., Framing, Roofing)

Weather Conditions

Roof Plan Review

2 of 10

Verification of the drainage system against approved roof plans and specifications.

Describe the roof drainage plan details (e.g., gutter size, downspout locations, scupper placement)

Upload a copy of the approved roof drainage plan.

Does the installed drainage system match the approved plan?

Gutter Size (as per plan):

Number of Downspouts (as per plan):

Are downspout locations as per plan?

If discrepancies exist, please detail them here:

Gutters & Downspouts - Visual Inspection

3 of 10

Assessment of gutters and downspouts for physical damage and proper alignment.

Gutter Sagging/Deformation?

Gutter/Downspout Alignment?

Gutter/Downspout Damage (linear feet)

Description of any visible damage (e.g., cracks, dents)

Evidence of previous repairs?

Location of observed damage (GPS coordinates)

Gutters & Downspouts - Debris & Flow

4 of 10

Evaluation of debris accumulation and proper water flow through the gutter system.

Type of Debris Observed (Check all that apply)

If 'Other' Debris selected, please specify:

Water Flow Condition

Describe any observed flow restrictions:

Estimated Debris Volume (Cubic Feet)

Gutter Slope Verification

Downspout Discharge & Grading

5 of 10

Verification of downspout discharge points and surrounding ground grading.

Downspout Discharge Point 1 Location (GPS)

Distance from Downspout to Foundation (ft)

Discharge Method

If 'Other' discharge method, please describe:

Slope of Grading Away from Foundation (%),

Evidence of Erosion/Water Pooling?

If Yes, describe location and severity of erosion/pooling.

Photo of Downspout Discharge & Grading

Roof Scuppers (if applicable)

6 of 10

Inspection of roof scuppers for blockages and proper function.

Scupper Location(s) Verified?

Specify Scupper Locations (if 'Yes, some locations' selected)

Scupper Condition - Debris?

Scupper Outlet Size (inches)

Scupper Screen/Guard Present?

Screen/Guard Condition?

Comments Regarding Scupper Inspection

Internal Drains (if applicable)

7 of 10

Inspection of internal drainage systems for functionality and blockages.

Drain Type?

Drain Capacity (GPM)

Description of Drain Location

Drain Functioning Properly?

If 'No', Describe Drainage Issues

Upload Photo of Internal Drain (if issues present)

Drainage Flow Rate (Gallons/Minute)

Connections & Joints

8 of 10

Assessment of gutter, downspout, and scupper connections for leaks and integrity.

Gutter-to-Gutter Connections: Condition

Downspout-to-Gutter Connections: Condition

Downspout-to-Foundation/Ground Connections: Condition

Number of Leaks Observed (if any)

Detailed Description of Leak Locations/Concerns

Connection Type (e.g., Rivet, Clamp, Soldered)

Notes on Connection Material Integrity (corrosion, cracking)

Material Condition

9 of 10

Evaluation of the condition of gutter, downspout, and scupper materials (rust, corrosion, damage).

Gutter Material Type

If 'Other' material, please specify:

Evidence of Rust/Corrosion (Gutters)

Percentage of Gutter Surface with Rust/Corrosion

Evidence of Damage (Gutters)

Photo Evidence of Material Degradation

Downspout Material Type

If 'Other' downspout material, please specify:

Summary & Recommendations

10 of 10

Overall assessment and suggested corrective actions.

Overall Assessment Summary

Severity Rating (1-5, 1=Minor, 5=Critical)

Detailed Recommendations

Recommended Actions (Select all that apply)

Recommended Completion Date

Responsible Party (for corrective actions)

Inspector Signature

Notes (additional comments)

Ce modèle de liste de contrôle vous a-t-il été utile ?

Démonstration d'une solution de gestion de la construction

Construisez plus intelligemment, pas plus dur ! ChecklistGuro rationalise les projets de construction, de la planification à la clôture. Gérez les tâches, les inspections, les protocoles de sécurité et bien plus encore, le tout au même endroit. Réduisez les retards, améliorez la communication et livrez les projets dans les délais et dans le budget.

Modèles de liste de contrôle associés

Nous pouvons le faire ensemble

Besoin d'aide avec les listes de contrôle?

Vous avez une question ? Nous sommes là pour vous aider. Veuillez soumettre votre demande et nous vous répondrons rapidement.

E-mail
Comment pouvons-nous vous aider ?