Fire Suppression System Testing Checklist

Ensure life safety & regulatory compliance! Download our comprehensive Fire Suppression System Testing checklist - your essential Facility Management tool for inspections, maintenance, and documentation. Protect your building & occupants with expert guidance.

This Template was installed 5 times.

System Overview & Preparation

1 of 7

Initial checks and documentation review before commencing testing.

Date of Inspection

Start Time of Inspection

System Type (e.g., Wet, Dry, Pre-Action)

System Manufacturer

System Model Number

Review of Previous Inspection Reports & Maintenance Records

Ambient Temperature (°C)

Weather Conditions

Nozzle & Piping Inspection

2 of 7

Visual inspection of all nozzles, piping, and associated hardware.

Identify Location of First Nozzle Inspected

Nozzle Condition (First Inspected)

Number of Nozzles Inspected

Detailed Description of any Nozzle Damage/Corrosion/Obstruction

Piping Condition (General)

Detailed Description of any Piping Damage/Leaks/Sagging

Hangers/Supports Condition

Upload Photo of Any Issues Found

Water Supply Verification

3 of 7

Confirmation of adequate and reliable water supply for system operation.

Water Main Pressure (PSI)

Sprinkler System Pressure (PSI)

System Flow Rate (GPM)

Water Supply Type

Water Supply Adequacy

Notes/Observations regarding water supply

Date of Last Water Supply Hydrostatic Test

Hydrostatic Test Pressure (PSI)

Control Panel & Alarm System Checks

4 of 7

Evaluation of control panel functionality, alarm signals, and communication systems.

Panel Voltage (V)

Battery Voltage (V)

Panel Status

Supervisory Device Status

Functional Tests Performed (Select all that apply)

Alarm Signal Verification Notes

Last Panel Software Update

Sprinkler Head Testing (Discharge & Coverage)

5 of 7

Specific testing procedures for sprinkler heads, including discharge testing (as applicable) and coverage assessment.

Sprinkler Head Test Temperature (Ambient)

Sprinkler Head Test Method (If Applicable)

Sprinkler Head Observed Condition (e.g., corrosion, damage)

Discharge Pressure (PSI) - Sprinkler Head (if tested)

Discharge Time (Seconds) - Sprinkler Head (if tested)

Sprinkler Head Discharge Pattern

Description of any observed deficiencies in discharge or coverage

Sprinkler Head Coverage Adequate?

Special Hazard System Testing (If Applicable)

6 of 7

Testing for systems protecting specific hazards, such as clean agent systems or foam systems.

System Type (If Applicable)

Specify 'Other' System Type (If Selected)

Discharge Test Duration (Seconds)

Discharge Test Flow Rate (GPM/LPM)

Nozzle Integrity (Clean Agent/Foam)

Observations/Notes (Clean Agent/Foam)

Discharge Test Photo/Video

Last Maintenance/Service Date

Documentation & Reporting

7 of 7

Recording test results, identifying deficiencies, and tracking corrective actions.

Date of Test

Start Time of Test

Test Results Summary

Water Pressure (PSI)

Water Flow (GPM)

Deviations from Standard Procedure (If Any)

Deficiencies Found?

Corrective Actions Required

Supporting Documentation (e.g., flow charts, pressure readings)

System Status

We can do it Together

Need help with Checklists?

Have a question? We're here to help. Please submit your inquiry, and we'll respond promptly.

Email Address
How can we help?